loading

One Stop Solution Manufacturer for all kind of Stamping Products and CNC lathed products.

Analysis on the main methods of corrosion protection for metal tensile parts

What are the main methods of corrosion protection for metal tensile parts? The precise author tells you that you need to pay attention to several points in the production process of stretch parts: In today's society, stretch parts can be seen everywhere; the production process of stretch parts is also different. Among them, the stretch coefficient is one of the main technical parameters in the calculation of the production process of stretched parts, and is usually used to determine the sequence and number of stretches. There are many factors that affect the stretch coefficient m, including the characteristics of the stretched part, the relative thickness of the material, the stretching method (with or without the blank holder), the stretching time, the stretching speed, the punch radius and the die, lubrication, etc. In addition, in the production process of drawing parts, when tensile cracks occur, apply lubricant on the die (not in the punch), and apply a 0.013-0.018 mm plastic film on the die side of the workpiece. During the stretching process, cold work hardening occurs due to the cold plastic deformation of the workpiece, thereby reducing its plasticity and increasing its deformation resistance and hardness. In addition, unreasonable mold design requires intermediate annealing to soften the metal and restore plasticity. Annealing is usually carried out at low temperatures. There are two points to note in annealing: decarburization and oxidation. After the workpiece is oxidized, the oxide scale will reduce the effective thickness of the workpiece and increase the wear of the mold. When the company does not have the conditions, the general annealing method is generally adopted. In order to reduce the generation of oxide scale, the furnace should be fully annealed as much as possible. 1. Change the internal structure of the metal. For example, chromium and nickel are added to ordinary steel to make stainless steel. 2. Cover the metal surface with a protective coating. For example, spraying, electroplating or chemical methods on the metal surface to form a dense and corrosion-resistant oxide film. Electrochemical protection. Because metals have no electrons, the galvanic reactions that cause electrochemical corrosion of metals can be removed by using protected metals as the cathodes of reduction reactions in electrochemical devices. The specific methods are: A, impressed current cathodic protection. The metal to be protected is connected to the negative electrode of the power supply through the electrolysis device, and the inert electrode is used as the anode. As long as the applied voltage is strong enough, the metal to be protected will not be corroded. B, the cathodic protection of the sacrificial anode. A new type of galvanic battery is composed of a protected metal and another metal that is more likely to lose electrons through the use of a galvanic device. When a galvanic reaction occurs, the crude metal is used as the positive electrode (ie, the cathode), which is protected and corroded by the external active metal-the negative electrode (ie, the anode). C. Corrosion inhibitors can slow down or prevent the corrosion of metal parts. Guangdong Precision Co., Ltd. is a manufacturer of precision metal and plastic parts. In order to ensure the high precision and accuracy of mass-produced parts, all of our progressive molds and plastic molds are developed, manufactured and used in production by our own team. In addition, we have also established an automation team to independently research and develop assembly automation equipment to achieve full-process automated production. [Related recommendation] Learn more: 精の corporate culture Learn more: Continuous improvement and innovation are the key factors for the survival of stamping companies Learn more: The development of the metal stamping processing industry

GET IN TOUCH WITH Us
recommended articles
Info Center Industry Service Blog
Did you know that the quality of lead frames has a significant impact on the precision and performance of your electronic devices? When it comes to choosing reliable lead frame manufacturers, there are several factors to consider.
Introduction:

Lead frames are an essential component in the manufacturing of high-performance parts for various industries.
Choosing the right lead frame manufacturer is crucial for the success and quality of your electronic devices.
Lead frame stamping is a critical process in the manufacturing of electronic components, especially as technology continues to advance at a rapid pace.
When it comes to precision stamping, lead frames are an essential component in many electronic and mechanical devices.
High-Quality Lead Frame Stamping for Electronics

The demand for high-quality lead frame stamping in the electronics industry continues to grow as companies strive to produce smaller, lighter, and more efficient electronic devices.
Expert Lead Frame Suppliers for Custom Stamping Projects

Are you in need of high-quality lead frames for your custom stamping projects? Look no further than our expert lead frame suppliers.
As of 2024, lead frame stamping services continue to play a critical role in the manufacturing and assembly of electronic components.
Future Trends in Lead Frame Stamping Technology

As technology continues to advance at a rapid pace, the world of lead frame stamping is no exception.
no data
Dongguan Fortuna was established in 2003. It has a factory area of 16,000 square meters and 260 employees. It is a production enterprise specializing in precision metal stamping parts, precision CNC processing, injection molding and product assembly.
Contact us
Japanese office
2-47-10-203Nishifunahashi, Hirakata City, Osaka
Adress
No. 226, Shida Road, Dalingshan Town, Dongguan 523810, Guangdong, China
Copyright © 2023 Dongguan Fortuna Metals Co, Ltd. - www.dgmetalstamping.com | Privacy Policy Sitemap
Contact us
email
contact customer service
Contact us
email
cancel
Customer service
detect